Back to top
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT
FLAMEPROOF LED EMERGENCY LIGHT

FLAMEPROOF LED EMERGENCY LIGHT

Price 14500.00 INR/ Number

FLAMEPROOF LED EMERGENCY LIGHT Specification

  • Control System
  • Automatic Emergency Switching Control
  • Cabinet Material
  • Die-cast Aluminium
  • Way
  • Single Way
  • Rated Insulation Voltage
  • 500V
  • Thickness
  • 4-7 mm (body wall thickness)
  • Cooling System
  • Passive
  • Protection Level
  • Flameproof, Weatherproof
  • Panel Type
  • LED Panel integrated
  • Operating Voltage
  • 220-240V AC
  • Features
  • Explosion Proof, Weather Resistant, Maintenance Free, LED indication
  • Connectivity Type
  • Hardwired
  • Current Rating
  • 0.5-1A
  • Rated Operation Voltage
  • 230V AC
  • Protection Class
  • Class I
  • Components
  • Inbuilt Rechargeable Battery, LED Lamp, Flameproof Enclosure
  • Rated Current
  • 0.5A
  • Cover Material
  • Toughened Glass Cover
  • Base Material
  • Aluminium alloy
  • Product Type
  • Flameproof LED Emergency Light
  • Material
  • Aluminium alloy die-cast
  • Surface Finish
  • Powder Coated
  • Standard
  • IS/IEC 60598, IS/IEC 60079 (Explosion Proof Standards)
  • Surface Color
  • Grey or customized as per requirement
  • Rated Voltage
  • 220-240V AC
  • Frequency (MHz)
  • 50 Hz
  • Maximum Output Current
  • 1A
  • Dimension (L*W*H)
  • 230 mm x 130 mm x 110 mm (approx.)
  • Application
  • Hazardous areas, Chemical plants, Refineries, Oil & Gas, Mines
  • IP Rating
  • IP66
  • Charge Time
  • 8-10 Hours
  • Number of LEDs
  • 8-24 (Depending on Model)
  • Mounting Type
  • Wall / Ceiling Mountable
  • Optics
  • Clear Toughened Glass Lens
  • Zone Suitability
  • Zone 1 & 2
  • Lamp Wattage
  • 6W/10W/18W (Available Options)
  • Weight
  • Approximately 3.5 kg
  • Gas Group
  • IIA, IIB
  • Emergency Duration
  • 2-4 Hours (Depending on Model)
  • Battery Type
  • Sealed Maintenance Free (SMF), Rechargeable
  • Operating Temperature Range
  • -20°C to +50°C
 

FLAMEPROOF LED EMERGENCY LIGHT Trade Information

  • Minimum Order Quantity
  • 05 Number
  • Payment Terms
  • Others
  • Supply Ability
  • 10 Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • corrugated Box
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
  • Certifications
  • CIMFR/PESO/BIS
 

About FLAMEPROOF LED EMERGENCY LIGHT

Flameproof cum Weatherproof Emergency Tube Light Fixture is Suitable for up to 1 x 10 W LED lamps operated with Electronic circuit with Rechargeable Battery, Backup Max. Up to 1 HRS, enclosure is Die Cast Al. Alloy LM- 6 Construction. The Terminal and Re-lamping end Glass Retaining Ring cemented to a heat resistant tubular clear Glass And both end fixed by means of socket head Allen cap Stainless Steel Screws to the Terminal Enclosure and Re-lamping Cover. The Emergency tube light fixture is suitable for used in Zone 1 & 2 Hazardous area Gas group IIB.

CONFIRMING TO STD : IS/IEC 60079-0-2004, IS/IEC 60079-1-2007, IS/IEC 60529 -2001

M.O.C:

  • Housing - Die Cast Al. Alloy, Hammertoe Grey Powder coated.
  • Reflector - M.S CRCA plate White powder coated. (10 W LED Lamp Gear tray with Lamp Assy and Battery)
  • Glass- Heat resistant tubular clear Glass
  • Gasket - Neoprene Ring Gasket (Suitable to Main and Terminal Enclosure)
  • Mains Terminals - 2 way 15 A 02 Nos  Lilo Suitable to incoming Cable (up to 6.0 Sq.mm)
  • Hardware- External SS (HTS) for FLP Joints /Internal M.S Zinc Plated
  • Earthing- Internal 01 No. External 02 Nos. on main Enclosure (M 6 x 12 L Brass Screw & Plain Washer)
  • Wiring- PVC wire 16/0.2 mm suitable for lamp Holder Wiring
  • Wire Guards - MS Rods Sq welded with white powder coated
Electrical Parameters
  • Rated Voltage- 240 V AC
  • Frequency (Hz)- 50 Hz
  • Wattage- 10 W- 60 w
  • Cable Entries-02 Nos. M 20 x 1.5 Threads (01 Nos. M.S Zinc Plated plug provided)
  • Mounting - Wall / Ceiling MTG with Adjustable Clamp
  • Optional- Electronic Circuit and Battery
  • Weight - 4.5 kg (Approx)



Flameproof Design for Maximum Safety

Specifically engineered for hazardous areas, this LED emergency light features an explosion-proof, weatherproof enclosure made from die-cast aluminium and toughened glass. It is designed for Zone 1 and 2 hazardous locations, ensuring protection against flammable environments such as chemical plants and oil refineries. Certified to IS/IEC 60598 and 60079 standards, users can trust in its ability to withstand demanding conditions while maintaining system integrity.


Long-Lasting Rechargeable Performance

With a sealed maintenance-free (SMF) rechargeable battery, this emergency light ensures reliable operation for 2 to 4 hours, depending on the selected wattage and model. The integrated automatic emergency switching control guarantees illumination during outages, and the unit requires just 8-10 hours for a full recharge. LED indicators provide clear battery status, streamlining maintenance and maximizing uptime.


Versatile Installation & User-Friendly Operation

This emergency light is engineered for both wall and ceiling mounting, offering flexibility for various industrial infrastructure needs. Its passively cooled, single-way design, with hardwired connectivity and inbuilt battery system, simplifies installation and minimizes ongoing maintenance. Powder-coated finishes provide customizable aesthetic options while maintaining corrosion resistance in harsh operating environments.

FAQ's of FLAMEPROOF LED EMERGENCY LIGHT:


Q: How do I install the FLAMEPROOF LED Emergency Light in hazardous areas?

A: The light is designed for both wall and ceiling mounting using compatible hardware. Ensure installation in accordance with IS/IEC 60079 standards for explosive atmospheres, and connect to a 220-240V AC power supply. All wiring should be performed by qualified personnel familiar with hazardous area requirements.

Q: What is the typical emergency duration after a power failure?

A: Depending on the chosen model (6W, 10W, or 18W), the emergency light will operate for 2 to 4 hours on a fully charged battery, providing sufficient illumination for emergency evacuation or safety protocols.

Q: Where is this emergency light best utilized?

A: Ideal for hazardous zones such as chemical plants, refineries, oil & gas facilities, and mines, it is suitable for any setting classified as Zone 1 or Zone 2, Gas Group IIA or IIB. Its flameproof and weatherproof construction makes it reliably functional both indoors and outdoors.

Q: What is the process for recharging the battery, and how long does it take?

A: Once connected to the main AC power supply, the built-in automatic charging system recharges the sealed maintenance-free battery. A full recharge takes approximately 8-10 hours, after which the light is ready for immediate use during an outage.

Q: How is automatic emergency switching managed in this product?

A: The integrated control system detects power outages and automatically switches to battery operation, illuminating the LEDs without user intervention. Upon power restoration, it reverts to charging mode, ensuring continuous readiness.

Q: What are the main benefits of choosing this emergency light for industrial applications?

A: The key advantages include explosion-proof and weatherproof certification (IP66), maintenance-free sealed battery, versatile installation options, clear LED indicators, compliance with global standards, and rugged construction engineered to withstand harsh environments. These features ensure enhanced safety, reliability, and reduced maintenance effort.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Flameproof Electrical Equipment Category

Flameproof proof Enclosure/Explosion proof  Enclosure

Flameproof proof Enclosure/Explosion proof Enclosure

Price 25000.00 INR / Piece

Minimum Order Quantity : 1 Number

Material : Other

Rated Voltage : 415 Volt (V)

Base Material : Other

Product Type : Junction Box

Flameproof Star Delta Starter

Flameproof Star Delta Starter

Price 100000 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Other

Rated Voltage : 440 Volt (V)

Base Material : Other

Product Type : Distribution Box

Flameproof Fan

Flameproof Fan

Price 9800 INR / Piece

Minimum Order Quantity : 01 Piece

Material : Other

Rated Voltage : 230 V /415 V AC Volt (V)

Base Material : Other

Product Type : Other

Flameproof Weather Proof Control Panel

Flameproof Weather Proof Control Panel

Price 10000 INR / Piece

Minimum Order Quantity : 1 Piece

Material : Metal

Rated Voltage : 110440 Volt (V)

Base Material : Other

Product Type : Electric Panel